were all below the secondaiy numeric criterion of 0.022 S/cc. The TEM PCMe results were
all below the primary numeric criteria of 0.0009 S/cc with one of the two samples being
below the detection limit.
Dioxin
Before Cleaning Samples - There were no before cleaning samples collected.
Post J" Cleaning Samples - There were no post- first cleaning samples collected
Gypsum
Before Cleaning Samples - There were no before cleaning samples collected.
Post J"' Cleaning Samples - There were two air samples collected after the first cleaning.
The results indicate that gypsum was not detected in any sample.
Lead
Before Cleaning Samples - There were no before cleaning samples collected.
Post J" Cleaning Samples - There were two air samples collected after the first cleaning.
The two air samples were below the detection limit.
Alpha-Quartz
Before Cleaning Samples - There were no before cleaning samples collected.
Post P' Cleaning Samples - There were two air samples collected after the first cleaning. All
of the samples were below the detection limit.
Calcite
Before Cleaning Samples - There were no before cleaning samples collected.
Post P' Cleaning Samples - There were two air samples collected after the first cleaning. All
of the samples were below the detection limit.
Cristobalite
Post P' Cleaning Samples - There were two air samples collected after the first cleaning. All
of the samples were below the detection limit.
Tridymite
Before Cleaning Samples - There were no before cleaning samples collected.
Post P' Cleaning Samples - There were two air samples collected after the first cleaning. All
of the samples were below the detection limit.