substantially below the numeric criterion and the MMVF in settled dust was reduced after the
first cleaning, no additional samples were collected for MMVF.
PAHs
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three
samples were below the detection limit and the TEF for each sample was below the numeric
criterion.
Post J" Cleaning Samples - There were four wipe samples collected after the first cleaning.
All of the samples were below the detection limit and the TEE for each sample was below the
numeric criterion of 300 pg/in^. Since all of the samples were below the detection limit and
the numeric criterion after the first cleaning, no additional samples were collected for PAHs.
Total Dust
Before Cleaning Samples - There were three pre-cleaning wipe samples collected; however,
EPA only requested to have one of the samples analyzed. The results indicate that there was
dust present.
Post P' Cleaning Samples - There were four wipe samples collected after the first cleaning;
however, EPA only requested to have two of the samples analyzed. Both samples indicate
that dust was present and slightly lower than the pre-cleaning concentration. As total dust
does not have a numeric criterion and the results indicate that some reduction was achieved,
no additional samples were collected for total dust.
Second Floor Hallway - The second floor hallway is an area with vinyl tiles on the floor, and walls
made of sheet rock covered with wallpaper glue. The ceiling is also made of sheet rock, and is
painted.
Cleaning method - This area was cleaned using test method 4A and test method 4B. Test
method 4A used an industrial HEPA filtered vacuum and an AFD. Test method 4B was a
soap and water wet wipe of the ceiling and floor only.
Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound
after being cleaned once.
Asbestos
Before Cleaning Samples - There were no before cleaning samples collected.
Post P' Cleaning Samples - There were two post-cleaning air samples collected. The two air
samples were analyzed using PCM, TEM AHERA, and TEM PCMe. The PCM results were
all below the secondary numeric criterion of 0.01 f/cc. Similarly, the TEM AHERA results
37