INTERNAL REVIEW DRAFT

substantially below the numeric criterion and the MMVF in settled dust was reduced after the first cleaning, no additional samples were collected for MMVF.

PAHs Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three samples were below the detection limit and the TEF for each sample was below the numeric criterion.

Post J" Cleaning Samples - There were four wipe samples collected after the first cleaning. All of the samples were below the detection limit and the TEE for each sample was below the numeric criterion of 300 pg/in^. Since all of the samples were below the detection limit and the numeric criterion after the first cleaning, no additional samples were collected for PAHs.

Total Dust Before Cleaning Samples - There were three pre-cleaning wipe samples collected; however, EPA only requested to have one of the samples analyzed. The results indicate that there was dust present.

Post P' Cleaning Samples - There were four wipe samples collected after the first cleaning; however, EPA only requested to have two of the samples analyzed. Both samples indicate that dust was present and slightly lower than the pre-cleaning concentration. As total dust does not have a numeric criterion and the results indicate that some reduction was achieved, no additional samples were collected for total dust.

Second Floor Hallway - The second floor hallway is an area with vinyl tiles on the floor, and walls made of sheet rock covered with wallpaper glue. The ceiling is also made of sheet rock, and is painted.

Cleaning method - This area was cleaned using test method 4A and test method 4B. Test method 4A used an industrial HEPA filtered vacuum and an AFD. Test method 4B was a soap and water wet wipe of the ceiling and floor only.

Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound after being cleaned once.

Asbestos Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There were two post-cleaning air samples collected. The two air samples were analyzed using PCM, TEM AHERA, and TEM PCMe. The PCM results were all below the secondary numeric criterion of 0.01 f/cc. Similarly, the TEM AHERA results

37

CITY_21MC100_004204993

NYC-WTC_000276689

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276689Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →