A side-bv-side test of the two different filter pore sizes to determine if overloading
was related to the filter pore size was inconclusive.
• In three of the sample sets, both the 0.45 micron and 0.8 filters were reported
as overloaded; in two of the samples sets, both the 0.45 and 0.8 filters were
reported with similar detections; in two other sample sets, both the 0.45 and
0.8 filters were returned overloaded or with similar detections; and in the
remaining two sample sets, one set had the 0.45 returned as non-detect and the
0.8 returned with a low-level detections, and the other set had the 0.45
returned with a low-level detection and the 0.8 was returned non-detect.
A comparison of flow rates to determine if there was a relationship between sample
pump flow rates, total air volume sampled, and sample overloading was inconclusive,
• In unit 3B, 0.8 micron asbestos sampling cassettes were run at a rate of 6, 8
and 10 liters per minute. Total volumes of 1000, 2000 and 3000 liters were
collected at each of the three flow rates. None of the cassettes overloaded
during the experiment.
A comparison of conducting vertical and horizontal wet wiping to horizontal only wet
wiping provided inconclusive with the exception of a large reduction in fibrous glass
(MMVF),
• In unit 3C the levels for asbestos wipes were greater by a factor of four than
the pre-sampling results. In unit 3B the levels for asbestos wipes were similar
or lower than the pre-sampling results.
• In units 3C and 3B there was a ~ 50% reduction in the MMVF concentration
pre and post cleaning.
Summary of Conclusions Based on the Data from Commercial Area Cleanings;
A test of vacuuming walls followed by wet-wiping demonstrated that vacuuming was
effective in reducing levels after the first cleaning and the additional wiping not
adding much value.
• Results from Chiropractors’s Office indicate that following vacuuming,
asbestos wipe samples (S/cm-) collected from walls showed a substantial
decrease (145,625 vs 3,957), however, following wet wiping of the wall the
post-cleaning wipe sample showed an increase to 12,480. Dioxin results
remained virtually unchanged between cleanings. Both pre- and post-cleaning
sampling results for and gypsum indicated it was not detected. Silica (alpha
quartz), fibrous glass (MMVF) and calcite were reduced substantially after the
first cleaning with post cleaning sampling indicating either close to or below
detection limits. Lead wipe results indicated a reduction between both
cleanings with the numeric criterion being met after the first cleaning. PAH
wipes pre-cleaning were below the numeric criteria and after cleaning were
117
CITY_21MC100_004205073
NYC-WTC_000276769