NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 121 pages

COPCS report, NYC WTC chain of custody

Machine-extracted title · confidence 50%

Table of contents for contaminants of [name] report and building sections.

NYC-WTC_000276652–000276772
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

INTERNAL REVIEW DRAFT

because the PCMe samples were unable to be analyzed because the filters were overloaded with particulate matter. This indicates that the testing methodology associated with PCMe asbestos air sampling is very sensitive to particulate matter and that an indoor environment needs to be relatively clean of particulate matter to achieve valid PCMe results. Based on the compounds and testing methods chosen, the data suggests that using asbestos air samples as an indicator is the most sensitive of the methods, as it resulted in the largest percentage of recleanings, and that the addition of other compounds in the testing regime provides limited additional sensitivity (i.e., an additional 18%). Use of only lead as the indicator, would have resulted in four recleanings (4 second cleanings) - 36%. Use of only MMVF as the indicator, would have resulted in three recleanings (3 second cleanings and 1 third cleaning) - 36%. Use of only silica as the indicator, would have resulted in one recleaning (a second cleaning) - 9%. Use of any of the other compounds (PAHs or dioxin), would have resulted in zero recleanings.

A comparison of the average number of cleanings req uired to the average level of initial contamination within the unit suggests that more heavily contaminated units required more cleaning events to meet the clearance criteria. • Table 13, Residential Units that are More Heavily Contaminated (Lower Sum of Ranks) Required More Cleaning Events to Achieve the Clearance Criteria, A illustrates this conclusion.

The results suggest that the use of an Air Filtration Device during cleaning decreases the number of overloaded filters. • Table 14, The Use of an Air Filtration Device Reduces the Occurrence of Overloaded Air Sample Filters, illustrates this conclusion.

The results suggest that the use of an AFP during the cleaning event decreases the number of cleanings that are required to meet the clearance criteria. • Table 15, The Use of an Air Filtration Device Minimizes the Number of Cleanings Required to Achieve the Clearance Criteria, illustrates this conclusion.

A comparison of limited asbestos air samples that were collected using modified- aggressive and aggressive air disturbance techniques did not identify any trends. • Table 16, Comparison of Airborne Asbestos Samples Collected Using the Modified-Aggressive and Aggressive Air Disturbance Methods, illustrates this conclusion.

116

CITY_21MC100_004205072

NYC-WTC_000276768

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276768Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →