because the PCMe samples were unable to be analyzed because the filters
were overloaded with particulate matter. This indicates that the testing
methodology associated with PCMe asbestos air sampling is very sensitive to
particulate matter and that an indoor environment needs to be relatively clean
of particulate matter to achieve valid PCMe results. Based on the compounds
and testing methods chosen, the data suggests that using asbestos air samples
as an indicator is the most sensitive of the methods, as it resulted in the largest
percentage of recleanings, and that the addition of other compounds in the
testing regime provides limited additional sensitivity (i.e., an additional 18%).
Use of only lead as the indicator, would have resulted in four recleanings (4
second cleanings) - 36%. Use of only MMVF as the indicator, would have
resulted in three recleanings (3 second cleanings and 1 third cleaning) - 36%.
Use of only silica as the indicator, would have resulted in one recleaning (a
second cleaning) - 9%. Use of any of the other compounds (PAHs or dioxin),
would have resulted in zero recleanings.
A comparison of the average number of cleanings req uired to the average level of
initial contamination within the unit suggests that more heavily contaminated units
required more cleaning events to meet the clearance criteria.
• Table 13, Residential Units that are More Heavily Contaminated (Lower Sum
of Ranks) Required More Cleaning Events to Achieve the Clearance Criteria,
A illustrates this conclusion.
The results suggest that the use of an Air Filtration Device during cleaning decreases
the number of overloaded filters.
• Table 14, The Use of an Air Filtration Device Reduces the Occurrence of
Overloaded Air Sample Filters, illustrates this conclusion.
The results suggest that the use of an AFP during the cleaning event decreases the
number of cleanings that are required to meet the clearance criteria.
• Table 15, The Use of an Air Filtration Device Minimizes the Number of
Cleanings Required to Achieve the Clearance Criteria, illustrates this
conclusion.
A comparison of limited asbestos air samples that were collected using modified-
aggressive and aggressive air disturbance techniques did not identify any trends.
• Table 16, Comparison of Airborne Asbestos Samples Collected Using the
Modified-Aggressive and Aggressive Air Disturbance Methods, illustrates
this conclusion.