NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS. INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone; (212) 420-8119 Fax. (212) 420-6092
Project No.; 01-2102
Metcalfs Eddy Inc. ELAP Lab Code; 11029
Analyte: ASBESTOS
3WemerWay, Suite 310 NIOSH and AIHA Lab Code: 100273
Date Received: 9/28/01
Lebanon. NJ 08833 NVLAP Lab Code; 101953
Date Analyzed: 9/29/01
Batch #: 0109B385
SUMMARY OF ANALYTICAL RESULTS - PLM
Site: 3 World Financial Center - Floors 3-26
SAMPLE it
ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION /LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CUENTS SAMPLE#
14001 14th Floor/ South East/ Bruce Harting's GRAY/ YES 10% CHRY 10%
9/28/01 Corner Office/ Entrance Door/ Sample of WHITE CELL 10%
10957 Debris FBGL 15%
NFIB 65%
14-001
14002 14th Floor/ South East/ Misa Abe's GRAY NO 0% FBGL 25%
9/28/01 Cubicle/ Sample of Debris NFIB 75%
10958
14-002
14003 14th Floor/ South East/ Charles Reinhards/ GRAY/ NO 0% CELL 5%
9/28/01 Window/ Sample of Debris BROWN FBGL 10%
10959 NFIB 85%
14-003
14004 14th Floor/ South East/ Charles Reinhards/ BROWN NO 0% CELL 40%
9/28/01 Desk/ Sample of Debris NFIB 60%
10960
14-004
1NSUFRCIENT MATERIAL SUBMITTED **TEM RECOMMENDED “•NOT ANALYZED POSITIVE STOP
Sample Analysis bv: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chiysolile Asbestos PAPE = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis:
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolrte Asbestos CELL = Cellulose
■Melhrxl for the Detemnlnation of Asbestos in Bulk Building Materials" ANTH = Anthophylile Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116. July 1993. ORGM = Organic Material
WOLL = Wollastonite
Inslnimentation: HSHR = Horse Hair ■
OTHR = Other
Olympus PLM, Model BH-2/VM Slereomicroscope, Model
VM2 1x-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analylical Results" shall not be reproduced except in full, without the wrSte
approval of JLC Laboratory, and 9 must not be used by client to claim product endorsement by NVIAP or any agency of the U.S. Government. This method is not applicable Io
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as h percentage of the protected area. Ouanlilalion of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION; Other Tthers with optical properties similar to asbeslo . '
■may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or heated as non-asbestos containing.
Page 1 of 3