NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalf 8 Eddy Inc. ELAP Lab Code: 11029
Analyte; ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIHA Lab Code: 100273
Date Received; 9/29/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Date Analyzed: 9/29/01
Batch #: 0109B386
SUMMARY OF ANALYTICAL RESULTS - PLM
Site: 3 World Financial Center - Floors 3-26
SAMPLE It
ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION /LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LABtt
CLIENTS SAMPLE it
16005 16th Floor/ South East Comer Office/ BROWN NO 0% CELL 20%
9/27/01 Sample of Debris FBGL 15%
11071 NFIB 65%
16-005
16006 16th Floor/ Office Adjacent to South East GRAY NO 0% CELL 25%
9/27/01 Corner Office of North Side FBGL 15%
11072 NFIB 60%
16-006
16007 16th Floor/ Office Adjacent to South East GRAY NO 0% CELL 90%
9/27/01 Corner Office of North Side NFIB 70%
11073
16-007
16008 16th Floor/ Office Adjacent to South East GRAY NO 0% CELL 30%
9/27/01 Comer Office of West Side FBGL 25%
11074 NFIB 45%
16-008
•INSUFFICIENT MATERIAL SUBMITTED •TEM RECOMMENDED "•NOT ANALYZED POSITIVE STOP
Sample Analysis by: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysolile Asbestos PAPF= Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis'
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA • TREM = T remolile Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophyirte Asbestos NFIB = Non-Fibrous
USEPA/600/R-93/116, July 1933. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation; HSHR = Horse Hair
6)^- Vi \* OTHR = Other
Olympus PLM. Model BH-2/VM Stereomicroscope, Model
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
. Analytical results reflect the make up the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in tull, without the vyritte
approval of JLC Laboratory, arid it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of fine, fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos
and Ihe semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION; Other fibers with optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
■ similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently Ihe only method that can be used Io determine if this material can b
considered or treated as non-asbeslos containing.
Page 2 of 3
CITY_21MC100_002821068
NYC-WTC_000268978