NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York. Nevy York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalfs Eddy Inc. ELAP Lab Code: 11029 Analyte: ASBESTOS
3 Werner Way. Suite 310 NIOSH and AIHA Lab Code: 100273 Date Received: 9/28/01
Lebanon. NJ 08833 NVLAP Lab Code: 101953 Date Analyzed: 9/28/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0109B383
Site; 3 World Financial Center - Floors 3-26
SAMPLE#
ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION/LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE #
26005 26th Floor/ Eastern Terrace/ Center of CREAM YES 20% CHRY 20%
9/27/01 Terrace/ Sample of Debris FBGL 40%
10930 CELL 5%
NFIB 35%
26-005
26006 26th Floor/ Eastern Terrace/ Center of TAN NO 0% FBGL 80%
9/27/01 Terrace/ Sample of Debris NFIB 20%
10931
26-006
26007 26th Floor/ Eastern Terrace/ North Side of GRAY/ NO 0% CELL TRACE
9/27/01 Terrace/Sample of Debris WHITE FBGL 85%
10932 NFIB 15%
26-007
26008 26th Floor/ Eastern Terrace/ North Side of CREAM/ NO 0% FBGL 3%
9/27/01 Terrace/ Sample of Debris BROWN CELL 15%
10933 NFIB 82%
26-008
’INSUFFICIENT MATERIAL SUBMITTED "TEM RECOMMENDED ***NOT ANALYZED POSITIVE STOP
ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MlbWV = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = AnthophyiiteAsbestos NFIB=Non-Fibrous
USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
rw yfn OTHR = Other
Olympus PLM, Model BH-2A/M Stereomicroscope, Model
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the writfe
approval of JLC Laboratory, and it must not be used by client to daim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quarrtitative identification of asbestos
and the semi-quantitative, determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers wrth optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.
Page 2 of 3
CITY_21MC100_011914220
NYC-WTC_000357520
OCR can misread numbers and units. Confirm readings against the page image before using them.