JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone; (212)420-8119 Fax:(212)420-6092
Project No.: 01-2102
Metcalf S Eddy Inc. ELAP Lab Code; 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and MH.A Lab Code: 100273 9/28/01
Date Received;
Lebanon, NJ 08833 NVLAP Lab Cc Ie; ' 01953
Date Analyzed: 9/28/01
0109B383
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #:
Site: 3 World Financial Center - Floors 3-26
SAMPLE #
ASBESTOS TOTAL % OF mMCTiTlifnts
DATE DESCRIPTION / LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE#
26009 26th Floor/ Eastern Terrace/ North Side of WHITE/ NO 0% CELL 2%
9/27/01 Terrace/ Sample of Debris BROWN NFiB 98%
10934
26-009
INSUFFICIENT MATERIAL SUBMITTED "TEM RECOMMENDED ***NOT ANALYZED POSITIVE STOP
ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos P/\PF = Paper Fiber
AMOS = /Vnosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FB6L = Fiberglass
Method of Sample Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophylite Asbestos NFIB = Mon-Fibrous
USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2/VM Stereomicroscope, Model
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of /Analytical Results” shall not be reproduced except in full, without the writte
approval of JLC Laboratory, and it must not be used by clienl to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of Fine fibers below the resolution cd the light microscope. The value of this method is limited to the quantitative identification of asbestos
and the semi-quantHative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. /Use, PLM is not consistently reliable in detecb'ng asbestos In floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.