NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS. INC. 200 Park Avenue South. Suite 1001, New York. New York 10003 Phone; (212) 420-8119 Fax: (212) 420-6092 Project No.; 01-2102 Metcalf & Eddy Inc. ELAP Lab Code: 11029 Analyte: ASBESTOS 3 Werner Way, Suite 310 NIOSH and AIHA Lab Code; 100273 Date Received: 9/28/01 Lebanon, NJ 08833 NVLAP Lab Code; 101953 Date Analyzed; 9/29/01 Batch#: 0109B385 SUMMARY OF ANALYTICAL RESULTS - PLM Site: 3 World Financial Center- Floors 3-26

SAMPLE # ASBESTOS TOTAL % OF CONSTITUENTS DATE DESCRIPTION / LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS COLLECTED LAB#

CLIENT'S SAMPLE #

11009 11th Floor/ South East/ Office Right of GRAY NO 0% CELL 20% Conference Room/ Passage Way/ Sample FBGL 30% 9/28/01 NFIB 50% 10985 of Debris 11-009

*INSUFFICIENT MATERIAL SUBMITTED **TEM RECOMMENDED "*NOT ANALYZED POSITIVE STOP

ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS Sample Analysis fay: Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber AMOS = Amosite Asbestos MINW = Mineral Wool CROC = Crocidolite Asbestos FBGL = Fiberglass Method of Sample Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers At! samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose "Method for the Determination of Asbestos in Bulk Building Materials” ANTH = Anthophylite Asbestos NFIB = Non-Fibrous USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material WOLL = Wollastonite Instrumentation: HSHR = Horse Hair OTHR = Other Olympus PLM, Model BH-ZA/M Stereomicroscope, Model VMZ 1x-4x. Gulam Machhtwala Laboratory Director

Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the wiitte approval of JLC Laboratory, and it must not be used by dienl to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to' ■ samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification ofasbestos and the semi-quantHative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of'asbestos content was determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbesto may give positive interferences and will be considered asbestos under this methodology. Also. PLM is not consistently reliable in detecting asbestos in floor coverings and . similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b considered or treated as non-asbestos containing.

Page 3 of 3

CITY_21MC100_011914181

NYC-WTC_000208696

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000208696Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →