JLC ENVIRONMENTAL CONSULTANTS. INC.
200 Park Avenue South, Suite 1001, New York. New York 10003 ■
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalf & Eddy Inc. ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way. Suite 310 NIOSH and AIH.A Lab Code: 100273
Date Received; 9/28/01
Lebanon, NJ 03833 NVLAP Lab Code: 101953
Date Analyzed: 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0109B385
Site: 3 World Financial Center - Floors 3-26
SAMPLE #
ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION /LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE #
5009 5th Floor/ South East/ South East Window/ GRAY/ NO 0% CELL 15%
9/28/01 Sample of Debris WHITE FBGL 5%
11045 NFIB 80%
5-009
^NSUFFICIENT MATERIAL SUBMITTED **TEM RECOMMENDED “NOT ANALYZED POSITIVE STOP
Sample Analysis fay: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and AAaIvsis:
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials* ANTH = Anthophylilo Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993.
ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2/VM Steieomicroscope, Model
VMZ 1x-4x. Tjuiam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This ""Summary of Analytical Results" shall not be reproduced except in full, without the writto
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable Io
samples containing large amounts of fine fibers below the resolution.of the light microscope. The value of this method is limited to the quantitative identification of asbestos
and the semirquantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical propertiessimilar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.