NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-8119 Fax: (212) 420-6092

Project No.; 01-2102 Metcalfs Eddy Inc. ELAP Lab Code; 11029 Analyte: ASBESTOS 3 Werner Way, Suite 310 NIOSH and .AIH.A !.eb Code: 100273 Date Received; 9/28/01 Lebanon, NJ 08833 NVLAP Lab CocL- 101953 Date Analyzed: 9/29/01 Batch #: 0109B385 SUMMARY OF ANALYTICAL RESULTS - PLM

Site: 3 World Financial Center - Floors 3-26

SAMPLE « ASBESTOS TOTAL % OF CONSTITUENTS DATE DESCRIPTION / LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS COLLECTED LABH

CLIENT'S SAMPLE #

12009 12th Floor/ South East/ East Side-South/ GRAY NO 0% FBGL 25% 9/28/01 Mike Carter/ Sample of Debris NFIB 75% 10975 12-009

•INSUFFICIENT MATERIAL SUBMITTED "TEM RECOMMENDED ”*NOT ANALYZED POSITIVE STOP

ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS Sample Analysis by: Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber AMOS = Amosite Asbestos MINW = MBneralWool CROC = Crocidolile Asbestos FBGL = Fiberglass Method of Sample Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose "Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anihophylite Asbestos NFIB = Non-Fibrous USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material WOLL = Wollastonite Instrumentation: HSHR = Horse Hair OTHR = Other Olympus PLM, Model BH-2/VM Stereomicroscope, Model VMZ 1x-4x. Gulam MacJihiwala Laboratory Director

Analytical, results reflect the make up of the materials only in the areas sampled. This "Summary of Analyh’cal Results" shall not be reproduced except in full, without the writte approval of JLC Laboratory, and it must not be used by client Io claim product endorsement by NVLAP or any agency of the U.S. Government.’ This method is not applicable to samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative idenfification of asbestos and the semi-quantHative determination of asbestos content of bulk samples, expressed as a percentage of the protected drea Quantitation of asbestos content was ’ determined with a visual.volume eslimate. a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar Io asbesfo may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b considered or treated as non-asbestos containing.

Page 3 of 3

CITY_21MC1OO_O11914184

NYC-WTC_000208699

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000208699Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →