NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalfs Eddy Inc. ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIHA Lab Code: 100273
Date Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Date Analyzed: 9/28/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0109B383
Site: 3 World Financial Center - Floors 3-26
SAMPLE #
ASBESTOS TOTAL % OF roNSTITUPNTS
DATE DESCRIPTION / LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB It
CLIENT S SAMPLE »
26001 26th Floor/ Eastern Terrace/ South Side/ CREAM NO 0% CELL 2%
Sample of Debris FBGL 73%
9/27/01
NFIB 25%
10926
26-001
26002 26th Floor/ Eastern Terrace/ South Side/ TAN YES 9.1% CHRY 9.1%
9/27/01 Sample of Debris FBGL 55.9%
10927 CELL 10%
NFIB 25%
26-002
26003 26th Floor/ Eastern Terrace/ South Side/ TAN YES 20% CHRY 20%
9/27/01 Sample of Debris FBGL 45%
10928 CELL 5%
NFIB 30%
26-003
26004 26th Floor/ Eastern Terrace/ South Side/ BROWN NO 0% CELL 3%
9/27/01 Sample of Debris NFIB 97%
10929
26-004
’INSUFRCIEHT MATERIAL SUBMITTED **TEM RECOMMENDED "“NOT ANALYZED POSITIVE STOP
ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = CrotSdolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
- All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
. "Method for the Determination of Asbestos in Bulk Building Materials' ANTH = Anthophylite Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2A/M Stereomicroscope. Model
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results” shall not be reproduced except in full, without the writie
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government This method is not applicable to
. samples containing large amounts of fine fibers below the resolution of the light microscope; The value of this method is limited to the quantitative identification of asbestos-
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in iloor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron nnicroscopy is currently the only method that can be used to determine if this material can b.
considered or treated as non-asbestos containing.
Page 1 of 3
CITY_21MC100_011914219
NYC-WTC_000357519
OCR can misread numbers and units. Confirm readings against the page image before using them.