JLC ENVIRONMENTAL CONSULTANTS. INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalf & Eddy Inc. ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIHA Lab Code: 100273 Dale Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Date Analyzed: 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch ti: 0109B385
Site: 3 World Financial Center - Floors 3-26
SAMPLE #
DATE COLOR ASBESIOS TOTAL%OF CONSTITUENTS
DESCRIPTION / L OCA TION DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB It
CLIENT'S SAMPLE It
14005 14th Floor/ South East/ Charles Reinhards/ WHITE/ NO 0% FBGL 20%
9/28/01 East Window/ Sample of Debris BROWN NFIB 80%
10961
14-005
14006 14th Floor/ South East/ Bruce Harting/ BROWN/ NO 0% NFIB 100%
9/28/01 Window/ Sample of Debris WHITE
10962
14-006
14007 14th Floor/ South East/ Bruce Harting/ GRAY NO 0% CELL 20%
9/28/01 Window/ Sample of Debris NFIB 80%
10963
14-007
14008 14th Floor/ South East/ Misa Abe's BROWN/ NO 0% CELL 10%
9/28/01 Cubicle/ Sample of Debris WHITE NFIB 90%
10964
14-008
INSUFFICIENT MATERIAL SUBMITTED **TEM RECOMMENDED •"NOT ANALYZED POSITIVE STOP
Sample Analysis by: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPP = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis:
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophylile Asbestos NFIB = Non-Fibrous
USEPAZ 600/ R-93/116, July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2AIM Stereomicroscope. Model __
VMZ1X-4X. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the mafetials only In the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the wrilte
approval of JLC Laboratory.-and 3 must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method Is not applicable Io
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos
and the semi-quanlitalive determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos corrtent was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbesto
may give positive interferences and will bo considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coven'ngs and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used Io determine if this material can b
considered or treated as non-asbestos containing.
Page 2 of 3