JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax; (212) 420-6092
Project No.; 01-2102
Metcalfs Eddy Inc. ELAP Lab Code; 11029
Analyte; ASBESTOS
3WemerWay. Suite 310 NtOSH and AIHA Lab Code; 100273
Date Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code; 101953
Date Analyzed: 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch#: 01098385
Site; 3 World Financial Center- Floors 3-26
SAMPLE#
ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION / LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENTS SAMPLE #
14009 14th Floor/ South East/ Charles Reinhardt/ GRAY NO 0% NFIB 100%
9/28/01 Floor/ Sample of Debris
10965
14-009
^NSUFFICIENT MATERIAL SUBMITTED "TEM RECOMMENDED *~NOT ANALYZED POSITIVE STOP
Sample Analysis by: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis:
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials' ANTH = Anthophytite Asbestos NFIB = Non-Fibrous
USEPA/€00/R-93/116. July 1993. ORGM = Organic Material
WOLL = Woilastonile
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2/VM Slereomicrosoope, Model
VMZ 1x-4x. "Gulam Machhiwala
Laboratofy Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the writte
approval of JLC Laboratory, and it must not be used by client Io claim product endorsement by NVLAP or any agency.of tlie U.S. Government. This method is not applicable Io
samples containing large amounts of fine Ttbers below the resolution of the light microscope. The value of this method is limited Io the quantitative identification of asbestos
and the semi-quantitative determination of asbestos contertl of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar Io asbesto
■may give positive Interferences and will be considered asbestos under Ibis methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently, the only method that can be used to determine if this material can b
considered or treated as non-asbeslos containing.