Bulk sample analysis report, 31 [name] building

Machine-extracted title · confidence 46%

Bulk asbestos analysis of multiple samples from 31 [name], NYC-DCAS project; includes IDs and locations.

NYC-WTC_000268167–000268170
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 3540 S6th Street Long Island City IP i; s I NewYork,11106 1 Tel; (718)729-1997 Fax; (718)729-1876 w-

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 31 Chamber Street PROJECT#: Client Sample ID# : 11 12 13 14 15 Lab Sample ID# ; 010918D-1018 010918D-1019 010918D-1020 010918D-1021 010918D-1022 Sample Location: 5th Floor 5th Floor Middle 5th Floor 5th Floor 3rd Floor Middle Corner Window S.W. Window Sill South Elevator Bank "B" Facing South Window Room # Room # 504 Room # 504 East North Wing 301 Facing South

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Window Sill Window Sill Floor Dust Off Desk Window Sill Wipe Wipe Wipe Wipe Wipe

Color: Blk Blk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed

Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos; 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent): 3%SYNTH 2%CELL 5%CELL 5%SYNTH 3%SYNTH 8%SYNTH 8%CELL Non Fibr. Mat. (Percent): 97% 98% 87% 95% 89% Date Received: 9/18/01 Date of Analysis; 9/18/01 Date of Report: 9/18/01

Analystc Lab ManaMr; J Roody Lduis David Chen ♦ Analysis of samples is performed by Relarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) Y * Analytical equipments: Stereobinwular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-ffiable organically bound materials. Quantitative transmission electron microscooy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples, will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the witten approval of the laboratory. * The report must not be used by the client to claim endorsement by N VLAP or any agency of the U,S Government. W NYS-DOHELAP# 1127S NIST-M’LAPU ’62047 A/HA 100269

3

CITY_21MC1OO_OO6262354 NYC-WTC_000268169

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268169Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →