Bulk sample analysis report, 31 [name] building

Machine-extracted title · confidence 46%

Bulk asbestos analysis of multiple samples from 31 [name], NYC-DCAS project; includes IDs and locations.

NYC-WTC_000268167–000268170
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSIJUANTS 35-40 36thStre«t Long Island City NewYoik.mOO Tel: {718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 31 Chamber Street PROJECT#: Client Sample ID# : 6 7 8: 9 10 Lab Sample ID# : 010918D-1013 010918D-1014 010918D-1015 010918D-1016 010918D-1017 Sample Location: 7th Floor 7th Floor 5 th Floor Sth Floor 5th Floor Room ft 734 Room ft 73AA Ladies Bathroom North West Accounting Dept. North Mezzanine West Accounting Dept. West Room ft 508 Homogeneity: Yes Yes Yes Yes Yes Sample Description: Window Sill Window Sill Window Sill Dust of Desk Window Sill Wipe Wipe Wipe Wipe Wipe

Color: Blk BIk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None Nene None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 10%CELL <I%CELL 5%CELL lOYoSYNTH 5%SYNTH

Non Fibr. Mat. (Percent): 90% >99% S5% 90% 95% Date Received; 9/18/01 Date of Analysis: 9/18/01 Date of Report: 9/18/01

Analys Lab Manager; Roodv Louis * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) / * Analytical equipments: Stereobinocul^rmicroscope (MEIJI EMT-Serial ft 25930). Polarized Light M icroscope (MEIJI ML-POL-Serial ft 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-ffiable organically bound materials. Quantitative transmission electron microscopy lis currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. W NYS-DOH ELAP ft 11273 NlST-NyLAP ft 1020A7 AIHAif: 100269

2

CITY_21MC100_006262353

NYC-WTC_000268168

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268168Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →