NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Bulk sample analysis, 60 [name], DCAS, 0109/01

Machine-extracted title · confidence 44%

Bulk sample analysis report for NYC-DCAS at 60 [name], listing Lab Sample IDs and floors.

NYC-WTC_000268213–000268216
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUUfTS 35.4036tliStrMt Long Island City NswYotWM Tel: (718)729-1997 Fax:(718)729-1876 w

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 60 Laffayette Street PROJECT#: Client Sample ID# : 11 12 13 14 15 Lab Sample ID# : 010919A-1112 010919A-1113 01O919A-1114 010919A-1115 010919A-1116 Sample Location: Room 9-5D Room #9A Ftoom # 6Ci6 Room # 5DI Room # C5D1 North 9th Floor 6th Floor East 5th Floor 9th Floor File Cabinet Sth Floor

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Window Sill File Cabinet Window Sill Window Sill File Cabinet Wipe Wipe Wipe Wipe Wipe

Color: Blk Blk WEBIk WhBlk WKBlk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat (Type & Percent): 3%SYNTH 3%SYNTH 3%SYNTH 2%SYNTH 3%CELL 8%S'YNTH Non Fibr. Mat. (Percent): 97% 97% 97% 98% 89% Date Received: 9/19/01 Date of Analysis: 9/19/01 Date of Report: 9/19/01

Analyst: Lab Manager: ) Roody Lduis David Chen * Analysis of samples is performed byjmlarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate; of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. IB** NVS-DOH ELAP # 11273 MST-N^LAP # 10204 7 AIHA »: 100269

3

CITY_21MC100_0 06262439

NYC-WTC_000268215

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268215Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →