1 FA MX. KAMCONSUUANTS 3S-40 36th Stmt Long Island City NawYork,11106 Tel: (718)729-1997 Fax; (718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 60 Laffayette Street PROJECT#: Client Sample ID# : 6 7 8 9 10 Lab Sample ID# : 010919A-1107 010919A-1108 010919A-1109 010919A-1110 010919A-1111 Sample Location: Administrative Room 9A6 Floom 9A6 Room 9A8 Room #9-3D Judge Room 9th Floor So-ith East 9th Floor North 11th Floor 9th Floor 9th Floor

Homogeneity" Yes Yes Yes Yes Yes Sample Description: Window Sill Window Sill File Cabinet Window Sill Window Sill Wipe Wipe Wipe Wipe Wipe

Color: Blk Blk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

W Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent): 10%SYNTH 2%SYNTH 5%CELL 2%CELL 8%CELL 1%CELL 5“tSYNTH Non Fibr. Mat. (Percent): 90% 97% 53% 98% 87% Date Received: 9/19/01 Date of Analysis: 9/19/01 Date of Report:

Analyst: 9/19/01 -

Roodw ,ouis Lab Manager: David Chen * Analysis of samples is performed by IPolarized Light Microscopy (PEM) - Point Counting Method /2 (EPA 600/M4-82-020) X * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of repon shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. W NYS-DOH ELAP » 11273 NIST-N^LAP # 10204'7 AIHA #: 100269

2

CITY_21MC100_006262438

NYC-WTC_000268214

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268214Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →