BULK SAMPLE ANALYSIS REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: OFFICE BLDG -2 Laffayette, Manhattan, NY
PROJECT#:
Client Sample ID# : 6 7 8 9 10
Lab Sample ID# : 010917A-8I3 010917A-8I4 010917A-815 010917A-816 010917A-817
Sample Location: 12th Floor 9th Floor 7th Floor Lobby 7th Floor 7th Floor
Stair "W" Elevator Lobby By Elevator Stairway "Y" Stairs "W"
Homogeneity: Yes Yes Yes Yes Yes
Sample Description: Floor Floor Floor Floor Floor
Wipe Wipe Wipe Wipe Wipe
Color: Blk BIk Blk Blk Blk
Texture: Mixed Mixed Mixed Mixed Mixed
Sample Treatment: None None None None None
Asbestos Present:
(Type & Percen t) ND ND ND ND ND
Total Percent
Asbestos: 0% 0% 0% 0% 0%
Other Fibr. Mat.
(Type & Percent): 5%CELL 5%CELL .5%CELL 5%CELL 8%CELL
5%SYNTH 5%SYNTH
Non Fibr. Mat.
(Percent): 95% 90% 95% 95% 87%
Date Received: 9/17/0 i
Date of Analysis: 9/17/01
Date of Report: 9/17/01
Anal' Lab Manager:
David Chen
* Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method
(EPA 600/M4-82-020)
* Analytical equipments: Stereobinocular microscope (MEIJI EM.T-Serial # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
* PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-ffiable organically
bound materials. Quantitative transmission electron microscopv is cunently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
* The results relate only to the items calibrated or tested.
* The certificate of report shall not be reproduced without the written approval of the laboratory.
* The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government.
NYS-DOHELAP »11273 N/ST-NVLAP # 102047 AIHA#: 100269