Bulk sample analysis report, 60 [name], Sept 2001

Machine-extracted title · confidence 90%

Laboratory report detailing bulk sample analysis results for asbestos at 60 [name] in September 2001.

NYC-WTC_000182336–000182340
Page image
Scanned page image, NYC-WTC_000182338
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAUCOHSbUANTS 35'4036111 Street Long Island City NwYoik,11106 Tel: (718)729-1997 Fax: (718)723-1875

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 60 Laffayette Street PROJECT#: Client Sample ID# : 11 12 13 14 15 Lab Sample ID# : 0109I9A-11I2 0109I9A-III3 01()919A-l 114 OtO9I9A-lII5 0I09I9A-1I16 Sample Location; Room 9-5D Room #9A Room#6C16 Room # 5D1 Room # C5D1 North 9th Floor 6th Floor East 5th Floor 9th Floor File Cabinet Sth Floor

Homogeneity; Yes Yes Yes Yes Yes Sample Description; Window Sill File Cabinet V/indow Sill Window Sill File Cabinet Wipe Wipe V/ipe Wipe Wipe

Color; Blk Blk Wti/BIk Wh/Blk Wh-Blk Texture; Mixed Mixed Mixed Mixed Mixed Sample Treatment; None None None None None

'INH*' Asbestos Present; (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent): 3%SYNTH 3%SYNTH 3%SYNTH 2%SYNTH 3%CELL 8%SYNTH Non Fibr. Mat. (Percent): 97% 97% 97% 98% 89% Date Received: 9/19/01 Date of Analysi; 9/19/01 Date of Report; 9/19/01 Lab Manageiu^^-------- Analyst: Roody LjAiis David Chen * Analysis of samples is performed by^larized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) ----- * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement bv NVLAP or any agency of the US Government. NYS-DOH ELAP # 1127S NIST-NyiAP # 102.947 AIHA#: 100269

3

CITY_21MC100_006262424

NYC-WTC_000182338

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182338Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →