NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Bulk sample analysis report, Office Bldg-2 Lafayette, Oct 2001

Machine-extracted title · confidence 90%

Laboratory report detailing bulk sample analysis results for asbestos at Office Building 2 Lafayette in October 2001.

NYC-WTC_000182332–000182334
Page image
Scanned page image, NYC-WTC_000182334
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAW CONSULTANTS 35-40 36th Street Long Island City NewYork,11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: OFFICE BLDG.- 2 Laffayette, Manhattan, NY PROJECT#: Client Sample ID# II 12 13 Lab Sample : 010917A-818 OIO9l"A-8l9 ()1O917A-82O Sample Location: 3rd Floor Ground Floor (jt’ound Floor Elevator Lobby Bv Elevator =/5 Stair "Y"

Homogeneity: Yes Yes Yes Sample Description: Floor Foot Step Floor Wipe Wipe Wipe

Color: Blk BIk Blk Texture: Mixed Mixed Mixed Sample Treatment: None None None

ilH*' Asbestos Present: (Type & Percent) ND ND ND Total Percent Asbestos: 0% 0% (1%

Other Fibr. Mat. (Type & Percent): 10%CELL IO%CELL 10%CELL 5%SYNTH 5%SYNTH Non Fibr. Mat. (Percent): 90% 85% 85% Date Received: 9/17/01 Date of Analysis: 9/17/01 Date of Report: 9/17/01

Anal •«e .OU varas Lab Man 'er: A._ David Chen * Analvsis of samples is performed by Polarized Light Microsccpv (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. yyS-DOH ELAP #11273 MST-i\rLAP # 1O2>94'7 AIHA #: 100269

3

CITY_21MC100_0 06262419

NYC-WTC_000182334

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182334Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →