NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 5 pages

Bulk sample analysis report, 60 [name], Sept 2001

Machine-extracted title · confidence 90%

Laboratory report detailing bulk sample analysis results for asbestos at 60 [name] in September 2001.

NYC-WTC_000182336–000182340
Page image
Scanned page image, NYC-WTC_000182339
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAWCONSUL’ANTS 35-40 36th Street Long Island City NewYork.11106 Tel; (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 60 Laffayette Street PROJECT#: Client Sample IDff : 16 17 18 19 20 Lab Sample ID# : 010919A-1117 010919A-1118 010919A-1119 010919A-1120 010919A-1121 Sample Location; Room UC17 Room #C18 3rd Floor Field Blank Field Blank East 3rd Floor 3rd Floor Corridor by East Door C3

Homogeneity; Yes Yes Yes Yes Yes Sample Description; Window Sill Desk Window Sill Wipe Wipe Wipe Wipe Wipe

Color; Wh/Blk Wh/Blk Wh/Blk Blk Blk Texture; Mixed Mixed Mixed Non Fibrous Non Fibrous Sample Treatment; None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbe.stos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent); 5%CELL 7%SYNTH 5%SYNTH 0% 0% 10%SYNTH Non Fibr. Mat. (Percent): 85% 93% 95% 100% 100% Date Received: 9/19/01 Date of Analysis: 9/19/01 Date of Report; 9/19/01

Analyst: Lab Man ;er: Roody Lonis David Chen * Analysis of samples is performed by Edtarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: StereoWnocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-ffiable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP 11273 NrST-N^LAP # 102047 AIHA #: 100269

4

CITY_21MC100_0 06262425

NYC-WTC_000182339

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182339Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →