NYC 9/11 Public Portal Document
KAMCONSUIJANTS
35'4(136lh^reet
Long Island City
NewYork, 11106
Tel: {718 729-1997
Fax: (718 729-1876
BULK SAMPLE ANALYSIS REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: I Centre Street, Manhattan, New York
PRO^IECT#:
Client Sample ID# : 11 12 13 14 15
Lab Sample ID# : 010929A-17 010929A-18 010929A-19 010929A-20 010929A-21
Sample Location: 28th Floor 28th Floor 28th Floor 29th Floor 29th Floor
North North North South South
Homogeneity: Yes Yes Yes Yes Yes
Sample Description: Window Sill Window Sill Furniture Window Sill Window Sill
Wipe Wipe Wipe Wipe Wipe
Color: Blk Blk Blk Blk Blk
Texture: Mixed Mixed Mixed Mixed Mixed
Sample Treatment: None None None None None
Asbestos Present:
(Type & Percent) ND ND ND ND ND
Total Percent
Asbestos: 0% 0% 0% 0% 0%
Other Fibr. Mat.
(Type & Percent): 10%SYNTH 5%SYNTH 10%SyNTH 10%SYNTH 7%SYNTH
1%CELL 2°/cCELL 8%CELL
Non Fibr. Mat. <1%FBGL 1%FBGL
(Percent): 88% 95% 87% 82% 93%
Date Received: 9/29/01
Date of Analysis: 10/1/01
Date of Report:
Analyst:
10/1/01
RoodyLouia
Lab Manage^
David Chen
* Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method
(EPA 600/M4-82-020)
A
* Analytical equipments: Stereobindcular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
* PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials. Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
Samples will be stored for ninety (90) days and then returned to the client upon request
* The results relate only to the items calibrated or tested.
* The certificate of report shall not be reproduced without the written approval of the laboratory.
* The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government.
W
NYS'-DOH ELAP # 11273 NIST-NYLAP# 102047 AIHA #: 100269