NYC 9/11 Public Portal Document
35*«)36(hSlmt
Long Island City
tl k
NewYork.tHM
Tel: {118)729-1997
Fax:(718)729-1876
BULK SAMPLE ANALYSIS REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: 100 Centre Street
PROJECT#;
Client Sample ID# : 6 8 9 10
Lab Sample ID# ■ 010918A-937 010918A-938 010918A-939 010918A-940 010918A-941
Sample Location Center Window North East North East South East Elevator Bank
17th Floor Stairwell "A" Elevator Stairway "D" "A"
14th Floor 14th Floor 14th Floor 14th Floor
Homogeneity- Yes Yes Yes Yes Yes
Sample Description Window Sill Floor Window Sill Stairway Floor Floor
Wipe Wipe Wipe Wipe Wipe
Color Blk Blk BIk Blk Blk
Texture Mixed Mixed Mixed Mixed Mixed
Sample Treatment. None None None None None
Asbestos Present:
(Type & Percent) ND ND ND ND ND
Total Percent
Asbestos: 0% 0% 0% 0% 0%
Other Fibr. Mat
(Type (St Percent)- 28%CELL 1%CELL 3%CELL 5%SYNTH 3%SYNTH
5%SYNTH I0%SYNTH 5%SYNTH
Non Fibr Mat
(Percent): 67% 89% 92% 95% 97%
Date Received- 9/18/01
Date of Analysis 9/18/01
Date of Report 9/18/01
Analyst:' Lab Manag^tx
Roodv Uouis David Chen
* Analysis of samples is performed by tfolarized Light Micro .copy (PLM) - Point Counting Method
(EPA 600/M4-82-020) /
* Analytical equipments: StereobiWScuIar microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
* PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials. Quantitative transmission electron micros :opy is currentiy the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
* The results relate only to the items calibrated or tested.
* The certificate of report shall not be reproduced without the written approval of the laboratory
♦ The report must not be used by the client to claim endorsemi'nt by NVLAP or any agency of the US Government
NYS-DOH ELAP 11273 MST-!\rLAPtf 192047 AIHA#: 100269
CITY_21MC100_002777749
NYC-WTC_000182067
OCR can misread numbers and units. Confirm readings against the page image before using them.