NYC 9/11 Public Portal Document
KAM CONSULTANTS
35-4(136thStfMt
Long Island City
NewYork.fflOS
Tel: (718)729-1997
Fax:(718)729-1876
BULK SAMPLE ANALYSIS REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: 1 Centre Street, Manhattan, New York
PRO.rECT#:
Client Sample ID# : 16 17 18 19 20
Lab Sample ID# : 010929A-22 010929A-23 010929A-24 0I0929A-25 010929A-26
Sample Location; 29th Floor 29th Floor 29th Floor 29th Floor 29th Floor
. South West West West North
Homogeneity: Yes Yes Ye^s Yes Yes
Sample Description; Furniture Window Sill Window Sill Furniture Window Sill
Wipe Wipe Wipe Wipe Wipe
Color; Blk Blk Blk Blk Blk
Texture: Mixed Mixed Mixed Mixed Mixed
Sample Treatment: None None Nene None None
Asbestos Present:
(Type & Percent) ND ND ND ND ND
Total Percent
Asbestos: 0% 0% 0% 0% 0%
Other Fibr. Mat.
(Type & Percent): 10%SYNTH 5%CELL 5%CELL 15%SYNTH 10%SYNTH
1%CELL <1%SYNTH 5%CELL
Non Fibr. Mat.
(Percent): 89% 95% 94% 80% 90%
Date Received: 9/29/01
Date of Analysis: 10/1/01
Date of Report: 10/1/01
Analyst: 2^
Roody Lour )
Lab Manager:) I 4
David Chen
J.
* Analysis of samples is performed by PoK irized Light Microscopy (PLM) - Point Counting Method
(EPA 600/M4-82-020)
* Analytical equipments: StereoUuiocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
* PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials. Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
* Samples will be stored for ninety (90) days and then returned tc the client upon request
* The results relate only to the items calibrated or tested.
* The certificate of report shall not be reproduced without the written approval of the laboratory.
* The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government.
w NYS-DOH ELAP # 11273 NIST-NVLAP# 102047 AIHA #: 100269
4
CITY_21MC100_0 06262236
NYC-WTC_000182322
OCR can misread numbers and units. Confirm readings against the page image before using them.