Bulk sample analysis report, 100 Liberty Street, Sep 2001

Machine-extracted title · confidence 95%

Laboratory report detailing the results of bulk material samples collected from the 17th floor of 100 Liberty Street.

NYC-WTC_000182066–000182071
Page image
Scanned page image, NYC-WTC_000182068
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

35-40 36th Stmt /^kz. Long Island City

''if k. NewYork,11106 Tsi: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 100 Centre Street PROJECT#: Client Sample ID# : II 12 13 14 15 Lab Sample ID# 0I0918A-942 010918A-943 010918A-944 010918A-945 010918A-946 Sample Location' Hallway Desk South Room North Room Staircase "A" Elevator "B" South #1128 ff 1106 11th Floor 11th Floor 11 th Floor 11 th Floor 11th Floor

Homogeneity Yes Yes Yes Yes Yes Sample Description Desk Floor W indow Sill Floor W'lndow Sill Wipe Wipe W ipe VV ipe W ipe

Color BIk Blk BIk Blk Blk Texture Mixed Mixed Mixed Mixed Mixed Sample Treatment None None None None None

Asbestos Present' (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent)' 5%CELL 10%CELL 5%CELL 3%CELL 1%CELL

Non Fibr Mat (Percent): 95% 90% 95% 97% 99% Date Received: 9/18/01 Date of Analysis. 9/18/01 Date of Report.

Analyst 9/18/01

.c Roody Lout Lab Manager ) Z , . _ C David Chen * Analysts of samples is performed by Pol^ :ed Light Micrcscopv (PLM) - Point Counting Method (EPA 600/M4-82-020) / * Analytical equipments' StereobinoeWar microscope (MEIJ EMT-Serial ff 25930), Polarized Light Microscope (MEIJI ML-POL-Serial ff 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organicallv bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. !>JYS-DOH ELAP if 11273 MST-N^LAPff 102047 AIHA ff: 100269

3

CITY_21MC100_0 02777750

NYC-WTC_000182068

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000182068Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →