NYC 9/11 Public Portal Document
35-40 36th Stmt
/^kz. Long Island City
''if k.
NewYork,11106
Tsi: (718)729-1997
Fax:(718)729-1876
BULK SAMPLE ANALYSIS REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: 100 Centre Street
PROJECT#:
Client Sample ID# : II 12 13 14 15
Lab Sample ID# 0I0918A-942 010918A-943 010918A-944 010918A-945 010918A-946
Sample Location' Hallway Desk South Room North Room Staircase "A" Elevator "B"
South #1128 ff 1106 11th Floor 11th Floor
11 th Floor 11 th Floor 11th Floor
Homogeneity Yes Yes Yes Yes Yes
Sample Description Desk Floor W indow Sill Floor W'lndow Sill
Wipe Wipe W ipe VV ipe W ipe
Color BIk Blk BIk Blk Blk
Texture Mixed Mixed Mixed Mixed Mixed
Sample Treatment None None None None None
Asbestos Present'
(Type & Percent) ND ND ND ND ND
Total Percent
Asbestos: 0% 0% 0% 0% 0%
Other Fibr. Mat.
(Type & Percent)' 5%CELL 10%CELL 5%CELL 3%CELL 1%CELL
Non Fibr Mat
(Percent): 95% 90% 95% 97% 99%
Date Received: 9/18/01
Date of Analysis. 9/18/01
Date of Report.
Analyst
9/18/01
.c
Roody Lout
Lab Manager ) Z , . _ C
David Chen
* Analysts of samples is performed by Pol^ :ed Light Micrcscopv (PLM) - Point Counting Method
(EPA 600/M4-82-020) /
* Analytical equipments' StereobinoeWar microscope (MEIJ EMT-Serial ff 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial ff 88034)
* PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organicallv
bound materials. Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
* The results relate only to the items calibrated or tested.
* The certificate of report shall not be reproduced without the written approval of the laboratory.
* The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government.
!>JYS-DOH ELAP if 11273 MST-N^LAPff 102047 AIHA ff: 100269
3
CITY_21MC100_0 02777750
NYC-WTC_000182068
OCR can misread numbers and units. Confirm readings against the page image before using them.