NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Bulk sample analysis report, NYC-DCAS, 49-51

Machine-extracted title · confidence 53%

Bulk sample analysis report for NYC-DCAS project at 49-51 addresses.

NYC-WTC_000268177–000268180
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUANTS 35-40 3flh Street Long Island City NewYork,11106 Tel: (718)729-1997 Fax:(718)729-1876 Wm./

BULK SAMPLE ANALYSIS REPORT CLIENT; NYC-DCAS BUILDING ADDRESS: 49-51 Chamber Street PROJECT#: Client Sample ID" : 11 12 13 14 15 Lab Sample ID" : 0109I8C-994 010918C-995 3I0918C-996 0I0918C-997 01091 SC-998 Sample Location: Elevator Lobby Staircase "E" Elevator Lobby Staircase W. Elevator Lobby- West East East West West Sth Floor Sth Floor Sth Floor 5th Floor 5th Floor

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Floor Floor Floor Floor Floor Wipe Wipe Wipe Wipe Wipe

Color: Bm Blk Gr Gr Blk Texture: Mixed Mixed M ixed Mixed Mixed

Sample Treatment: None None None None None W Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos; 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent): 8%CELL 10%CELL 15%CELL 5%CELL 5%CELL 3%SYNTH Non Fibr. Mat. (Percent): 92% 90% 82% 95% 95% Date Received: 9/18/01 Date of Analysis; 9/18/01 Date of Report: 9/18/01

Analyst: 4 - - 1- Lab Man: ;er:

* Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) Z - * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. W NYS-DOH ELAP if 11273 NIST-N^LAP # 102047 AIHA#: 100269

3

CITY_21MC100_006262370

NYC-WTC_000268179

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268179Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →