Bulk asbestos analysis, NYC-DCAS, 100 [name]

Machine-extracted title · confidence 50%

Bulk sample analysis report of homogenized material from 100 [name], DCAS.

NYC-WTC_000268141–000268146
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-40 36th Street Long Island City New York,11106 Tel:pi8 729-W Fax: (718 729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 100 Centre Street PROJECT#: Client Sample ID# : 21 22 23 24 25 Lab Sample ID# : 010918A-952 010918A-953 010918A-954 010918A-955 010918A-956 Sample Location: Stairwell "D" South Rm.# 322 Corridor East Exit Room # 129A South 3rd Floor 3rd Floor Lobby Lobby 3rd Floor

Homogeneity; Yes Yes Yes Yes Yes Sample Description: Floor Window Sill Floor Floor Window Sill Wipe Wipe Wipe Wipe Wipe

Color; Blk Blk Blk Blk Blk Texture; Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent): 2%CELL 3%CELL 5%CELL 12%CELL 8%CELL 5%SYNTH Non Fibr. Mat. (Percent): 98% 97% 95% 88% 87% Date Received: 9/18/01 Date of Analysis: 9/18/01 Date of Report:

Analyst? 9/18/01

Roody Loui! Lab Managi David Chen Q * Analysis of samples is performed by Polarised Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobins ir microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non -asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsemen : by NVLAP or any agency of the US Government. NVS-DOHELAP# 11272 MST-Nf^LAP# 102047 AIHA ft: 100269

5

CITY_21MC100_0 06262298

NYC-WTC_000268145

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268145Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →