Bulk sample analysis, 1 Centre Street, Sept 2001

Machine-extracted title · confidence 33%

Bulk sample analyses for NYC-DCAS building at 1 Centre Street; multi-location floors.

NYC-WTC_000268120–000268126
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-40 36th Street Long Island City NewYork, 11106 Tel: (718)729-1937 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 1 CENTRE STREET PROJECT#: Client Sample ID# ; 26 27 28 29 30 Lab Sample ID# ; 010917B-846 O10917B-847 0109178-848 010917B-849 0109178-850 Sample Location: 5th Floor 5th Floor Ground Floor Ground Floor Ground Floor North corridor East Elevator North Elev. North Elevator North Elevator Stair "A" Lobby Lobby West Lobby Lobby West Exit Exit Homogeneity; Yes Yes Yes Yes Yes Sample Description: Door Step Sill Floor Floor Floor Wipe Wipe Wipe Wipe Wipe

Color: BIk BIk BIk BIk BIk Texture; Mixed Mixed Mi;<ed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent); 5%SYNTH 10%CELL 5%SYNTH 2%CELL 10%CELL 5%SYNTH Non Fibr. Mat. (Percent); 95% 85% 95% 98% 90% Date Received: 9/17/01 Date of Analysis; 9/17/01 Date of Report; 9/17/01

Analy^ .ouvaras Lab Mana^r: L- David Chen * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments; Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP# 11273 MST-NVLAP 0 102047 AfHAfi: 100269

6

CITY_21MC100_006262229

NYC-WTC_000268125

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268125Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →