Bulk asbestos analysis, NYC-DCAS, 100 [name]

Machine-extracted title · confidence 50%

Bulk sample analysis report of homogenized material from 100 [name], DCAS.

NYC-WTC_000268141–000268146
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35403BlhStrMt Long Island City N«wYorl[.1110« Tel: {718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 100 Centre Street PROJECT#: Client Sample ID# : 6 7 9 10 Lab Sample ID# : 010918A-937 010918A-938 0IO918A-939 010918A-940 010918A-941 Sample Location: Center Window North East North East South East Elevator Bank 17th Floor Stairwell "A" Elevator Stairway "D" "A" 14th Floor 14th Floor 14th Floor 14th Floor

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Window Sill Floor Window Sill Stairway Floor Floor Wipe Wipe Wipe Wipe Wipe

Color: Blk BIk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent): 28%CELL 1%CELL 3%CELL 5%SYNTH 3%SYNTH 5%SYNTH 10%SYNTH 5%SYNTH Non Fibr. Mat. (Percent): 67% 89% 92% 95% 97% Date Received: 9/18/01 Date of Analysis: 9/18/01 Date of Report: 9/18/01

Analyst:' Roody iJouis Lab Manag^ LZ-__ U David Chen * Analysis of samples is performed bv Polarized Lisht Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) / * Analytical equipments: Stereobihtlcular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) davs and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP # 11273 MST-Nf/LAP # 102047 AIHA U: 100269

2

CITY_21MC100_006262295

NYC-WTC_000268142

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268142Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →