Bulk asbestos analysis, NYC-DCAS, 100 [name]

Machine-extracted title · confidence 50%

Bulk sample analysis report of homogenized material from 100 [name], DCAS.

NYC-WTC_000268141–000268146
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUIJANIS 35-40 36th Street Long Island City NawYork, 11106 Tel; (718)729-1997 k Fax; 718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT; NYC DCAS BUILDING ADDRESS: 100 Centre Street PROJECT#: Client Sample ID# : 11 12 13 14 15 Lab Sample ID# : 010918A-942 010918A-943 01()918A-944 010918A-945 010918A-946 Sample Location: Hallway Desk South Room North Room Staircase "A" Elevator "B" South #1128 # 1106 11th Floor 11th Floor II th Floor 11th Floor 11th Floor

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Desk Floor V/indow Sill Floor Window Sill Wipe Wipe Wipe Wipe Wipe

Color: Blk Blk Elk Blk Blk Texture: Mixed Mixed Mi:«d Mixed Mixed Sample Treatment: None None None None None

Asbestos Present; (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 5%CELL 10%CELL 5%CELL 3%CELL 1%CELL

Non Fibr. Mat. (Percent); 95% 90% 95% 97% 99% Date Piece ived: 9/18/01 Date of Analysis: 9/18/01 Date of Report: 9/18/01

Analyst ■X-A.- Roody Louia Lab Manager: LA jL David Chen * Analysis of sa:mples is performed by Polled Light Microscooy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: StereobinochTar microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without the written approval of the laboratory. + The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP /f n27J MST-NVLAP # J02M7 AIHAff: ]00269

3

CITY_21MC100_0 06262296

NYC-WTC_000268143

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268143Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →