KAM CONSULTANTS 35-40 36th Street Long Island City NewYork,11106 Tel: (718)129-1997 Fax: 718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 280 Broadway, Manhattan, NY PROJECT#: Client Sample ID# : 31 32 33 34 35 Lab Example ID# : 010922B-1419 010922B-1420 010922B-1421 010922B-1422 010922B-1423 Sample Location: 4th Floor 4th Floor 4th Floor 4th Floor 4th Floor South Window South Window South West West Middle West Middle Window Window Window

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Window Sill A/C Window Sill Window Sill A/C Wipe Wipe Wipe Wipe Wipe

Color: BIk Blk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

W Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 2%CELL 5%CELL ;5%CELL 1%CELL 3%CELL 10%FBGL Non Fibr. Mat. (Percent): 98% 95% 95% 89% 97% Date Received: 9/22/01 Date of Analysis: 9/23/01 Date of Report: 9/24/01

Analyst: Lab Mana 1 UTan^i --------- David Chen * Analysis of samples is performed by Polarized Light Microscopv (PLM) - Point Counting Method (EPA 600/M4-82-020) / * Analytical equipments: SterttAinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 8«I34) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopv is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP# 11273 MST-NVLAP# 102017 AIHA#: 100269

7

CITY_21MC100_006262557

NYC-WTC_000268295

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268295Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →