Bulk sample analysis, 280 Broadway, Sept 2001

Machine-extracted title · confidence 40%

Bulk sample analysis results for 280 Broadway project, lab IDs 010922B-1389 to -1393.

NYC-WTC_000268289–000268299
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-40 36th Street Long Island City New York, WOO Tel: (718 729-1997 Fax: 718 729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 280 Broadway, Manhattan, NY PROJECT#: Client Sample ID# : 26 27 28 29 30 Lab Sample ID# : 010922B-1414 010922B-1415 010922B-1416 010922B-1417 010922B-1418 Sample Location: 6th Floor 6th Floor 6th Floor North/ 4th Floor 4th Floor Facing South North Window South Conidor South Window North Window Court Yard V/indow North Court Yard Window Homogeneity; Yes Yes Yes Yes Yes Sample Description: Window Sill Windowsill Window Sill Window Sill Window Sill Wipe Wipe V/ipe Wipe Wipe

Color: Blk Blk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment; None None None None None

•w Asbestos Present; (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent); 2%SYNTH 5%SYNTH 3%CELL 5%CELL 2%CELL

Non Fibr. Mat. (Percent): 98% 95% 97% 95% 98% Date Received: 9/22/01 Date of Analysis: 9/23/01 A Date of Report: 9/24/01

Analyst: Lab Manager; irk Ulanecki * Analysis of samples is perfori id bv Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Anahlical equipments; Stei binocular microscope (MEIJI EMT-Serial # 25930). Polarized Light Microscope (MEIJI ML-POL-Serial # 034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. ♦ The report must not be used bv the client to claim endorsement bv NVLAP or any agency of the US Government. NYS-DOH ELAP #11273 NIST-NVLAP# 102047 AIHA «: 100269

6

CITY_21MC100_0 06262556

NYC-WTC_000268294

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268294Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →