Bulk sample analysis, 280 Broadway, Sept 2001

Machine-extracted title · confidence 40%

Bulk sample analysis results for 280 Broadway project, lab IDs 010922B-1389 to -1393.

NYC-WTC_000268289–000268299
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS

1^^ 'J Pl k 35-40 36th Street Long Island City NewYork,11106 Tel: {718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 280 Broadway, Manhattan, NY PROJECT#: Client Sample ID# : 36 37 38 39 40 Lab Sample ID# : 010922B-1424 010922B-1425 C10922B-1426 010922B-1427 010922B-1428 Sample Location: 4th Floor 2nd Floor 2nd Floor Main Entrance Main Entrance North West South Window North Window Broadway Hall to Bldg. Broadway Window Comer

Homogeneity: Yes Yes Yes Yes Yes Sample Description: Window Sill Window Sill Window Sill Floor Door Step Wipe Wipe Wipe Wipe Wipe

Color: BIk Blk Blk Blk Blk Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment: None None None None None

■HKf Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr, Mat. (Type & Percent): 5%CELL 2%CELL 1%CELL 5%CELL 5%CELL

Non Fibr. Mat. (Percent): 95% 98% 99% 95% 95% Date Received: 9/22/01 Date of Analysis: 9/23/01 Date of Report: 9/24/01 I Analyst: Lab Manager: Ulanecki David Chen * Analysis of samples is perform! by Polarized Light Microscopy (PLMI - Point Counting Method (EPA 600/M4-82-020) , * Analytical equipments: Stereoo inocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-ffiable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the wr itten approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NiS-DOH ELAP # 11273 MST-NVLAP# 102047 AIHAli: 100269

8

CITy_21MC100_0 06262558

NYC-WTC_000268296

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000268296Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →