NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 13 pages

Bulk sample analysis report, 80 [name]

Machine-extracted title · confidence 43%

Bulk sample IDs and room labels for 80 [name], 8th Floor and East/West areas.

NYC-WTC_000266439–000266451
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

\AMVUN6UUArtli) 35-40 3«thStrNt Long Island City NewYork,11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 80 Centre Street, Manhattan, N\ PROJECT#: Client Sample ID# 16 17 18 19 20 Lab Sample 010922C-1454 010922C-1455 010922C-1456 010922C-1457 010922C-1458 Sample Location Sth Floor Stair Stair Landing 7th Floor Landing Stairs 6th Floor A F Staircase Freight Elevators F Be^veen 7th Freight Elevator Between 8 and 1 th Facing North & 6th Floor Floor Homogeneity Yes Yes Yes Yes Yes Sample Description Door Step Floor Door Steps Floor Door Step W ipe Wipe Wipe Wipe Wipe

Color Bik Blk Blk Bik BIk Texture Mixed Mixed Mixed Mixed Mixed Sample Treatment None None None None None

Asbestos Present. (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat (Type & Percent) 10%CELL 5%CELL 1%CELL 3%SYNTH 2%CELL

Non Fibr. Mat (Percent); 90%o 95% 99% 97% 98% Date Received: 9/22/01 Date of Analysis- 9/23/01 Date of Report- 9/24/01 Analyst: ■ 0^ Cvv\v-L^ \ Mark Ulanecki Lab Manaiger: f David Chen J * Analysis of samples is performed bv Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments. Stereobinocular microscope (MEIJ EMT-Serial ft 25930), Polarized Light Microscope (MEIJI ML-POL-Serial it 88034) * PLM is not consistently reliable in detecting asbestos in floar coverings and similar non-friable organically bound materials. (Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returm d to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used bv the client to claim endorsement bv NVLAP or any agency of the US Government. yrS-DOH ELAP ft 11273 NIST-y^LAP^ 102047 AIHA 100269

4

CITY_21MC100_002777800

NYC-WTC_000266442

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266442Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →