NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 7 pages

Bulk sample analysis report, 1 Centre Street, 2001

Machine-extracted title · confidence 48%

Air/bulk sample analysis for NYC-DCAS at 1 Centre Street, NYC, with lab IDs and location details.

NYC-WTC_000266360–000266366
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUIJANIS 35-10 36thS!reet Long Island City NewYork.11106 Tel:(718)729-W Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 1 CENTRE STREET PROJECT#: Client Sample ID# ' 16 17 18 19 20 Lab Sample ID» . 010917B-836 010917B-837 010917B-838 010917B-839 010917B-840 Sample Location 15th Floor. 15th Floor 5th Floor lOth Floor 10th Floor Mid West East Men’s North Elevator East Elev North West Room Lobby Lobby Corridor by 1008

Homogeneity’ Yes Yes Yes Yes Yes

Sample Description Sill Sill Sill Sill Floor Wipe Wipe Wipe Wipe Wipe

Color BIk BIk BIk BIk BIk

Texture; Mixed Mixed Mixed Mixed Mixed

Sample Treatment None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent). 5%SYNTH 10%CELL 10%CELL 5%SYNTH 10%CELL 5%SYNTH Non Fibr Mat (Percent). 95% 90% 90% 95% 85% Date Received. 9/17/01 Date of Analysis- 9/17/01 Date of Report- 9/17/01

Analyst: Lab Manager I ouvaras David Chen * Analysis of samples is perftTrmed bv Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Anal-ytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM IS not consistently reliable in detecting asbestos in fit or coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated a. non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without thi written approval of the laboratory. * The report must not be used bv the client to claim endorsement bv NVLAP or any agency of the US Government. NYS-DOH ELAP ft 11273 MST-iNP'LAP tt 102047 AIHA ff: 100269

4

CITY_21MC100_0 02777715

NYC-WTC_000266363

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266363Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.