NYC 9/11 Public Portal Document
KAMCONSUIW
35-40 36th Street
Long island City
New York. 11106
Tel:(718)J29W
Fax:(718)729-1876
BULK SAMPLE ANALYSIS REPORT
CLIENT: NYC-DCAS
BUILDING ADDRESS: 60 Centre Street, Manhattan, N f
PROJECT#:
Client Sample ID# ■ 4l 42 43 44 45
Lab Sample ID# 0109I9B-1I62 010919B-1I63 01O919B-1164 010919B-1165 010919B-1166
Sample Location Hallway 3rd Fl Halifax 3rd Fl Room 139 Room 139 Room 139
Elevators Elevators Top of Lokers Wall Vent Top of Desk
Window Sill Floor Exhaust
Homogeneity- Yes Yes Yes Yes Yes
Sample Description Dust Dust Dust Dust Dust
Wipe Vv’ipe Y ipe Wipe Wipe
Color Blk Blk Blk Blk Blk
Texture Mixed Mixed Mixed Mixed Mixed
Sample Treatment None None None None None
Asbestos Present.
(Type & Percent) ND ND ND ND ND
Total Percent
Asbestos; 0% 0% 0% 0% 0%
Other Fibr. Mat
(Type & Percent): 2%CELL 2%SYNTH 5%SYNTH 5%CELL 6%CELL
5%CELL 8%CELL
Non Fibr. Mat
(Percent): 98% 93% 87% 95% 94%
Date Received. 9/19/01
Date of Analysis 9/19/01
Date of Report 9/19/01
Analyst; Lab Manager: I
Roodv Louis David Chen '
* Analysis of samples is performed b^Pprarized Light Microscopy (PLM) - Point Counting Method
(EPA 600/M4-82-020)
* Analytical equipments. Stereobinocular microscope (MEIJI EMT-Serial ft 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial ft 88034)
* PLM IS not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials. Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
* The results relate onlv to the items calibrated or tested
* The certificate of report shall not be reproduced without the written approval of the laboratory.
* The report must not be used bv the client to claim endorsement by NVLAP or any agency of the US Government.
i\YS-DOH ELAP# 11273 MST-NVLAP # 102047 AIHA ft: 100269
!)