Bulk sample analysis report, 1 Centre Street, 2001

Machine-extracted title · confidence 48%

Air/bulk sample analysis for NYC-DCAS at 1 Centre Street, NYC, with lab IDs and location details.

NYC-WTC_000266360–000266366
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAKCONSUIJANTS 35-«36th Street Long Island City NewYork.ltlOS Tel: {718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 1 CENTRE STREET PROJECT#: Client Sample ID^ 11 12 13 14 15 Lab Sample ID- 010917B-831 010917B-832 010917B-833 010917B-834 010917B-835

Sample Location 20th Floor 20th Floor 20th Floor 15th Floor 15th Floor South Receptionist West Corridor South Elevator South Elevator West Cabinet Desk Cabinet Lobby Lobby Next to 1576 Rm

Homogeneity Yes Yes Yes Yes Yes

Sample Description Furniture Furniture Floor Sill Furniture Wipe Wipe Wipe Wipe Wipe

Color Blk Blk Blk BIk BIk

Texture Mixed Mixed Mixed Mixed Mixed

Sample Treatment. None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr Mat. (Type & Percent) 5%SYNTH 5%SYNTH 5%SYNTH 5%SYNTH 5%SYNTH

Non Fibr Mat (Percent); 95% 95% 95% 95% 95% Date Received. 9/17/01 Date of Analysis. 9/17/01 Date of Report.

Analyst: 9/17/01

ivaras Lab Manaa^ j -jt A David Chen * Analysis of samples is performed by Polarized Light Micrcscopy (PLM) - Point Counting Method £ (EPA 600/M4-82-020) * Analytical equipments. Stereobinocular microscope (MEIJ EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in flcor coverings and similar non-friable organically bound materials Quantitative transmission electron micro; copy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) davs and then return ;d to the client upon request * The results relate only to the items calibrated or tested * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorserr ent by NVLAP or any agency of the US Government .WS-DOH ELAP tt 11273 MST-N^LAP# 02047 AIHA #; 100269

3

CITY_21MC1OO_OO2777714

NYC-WTC_000266362

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266362Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →