Bulk sample analysis report, 1 Centre Street, 2001

Machine-extracted title · confidence 48%

Air/bulk sample analysis for NYC-DCAS at 1 Centre Street, NYC, with lab IDs and location details.

NYC-WTC_000266360–000266366
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUUANTS 35-40 36thStreet

Jbk Long Island City NewYork,11106 Tel: (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 1 CENTRE STREET PROJECT#: Client Sample ID# .■ 6 7 8 9 lO

Lab Sample ID# • 010917B-826 010917B-827 010917B-828 0I0917B-829 010917B-830

Sample Location 20th Floor 20th Floor 20th Floor 20th Floor. 20th Floor. East Ladies North Secretary Mid Floor South/West West Commission Bathroom Desk Next to West Conference Office Conference Room Room Homogeneity' Yes Yes Yes Yes Yes

Sample Description Sill Desk Sill Furniture Sill W ipe Wipe W ipe ipe Wipe

Color. Blk BIk Blk Blk Blk

Texture Mixed Mixed Mixed Mixed Mixed

Sample Treatment. None None None None None

Asbestos Present. (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent). 5%SYNTH 5%SYNTH 5%SYNTH 2%CELL 5%SYNTH

Non Fibr. Mat. (Percent): 95% 95% 95% 98% 95% Date Received' 9/17/01 Date of Analysis. 9/17/01 Date of Report.

Analy^ 9/17/01

.ouvaras Lab Mana .J David Chen * Analysis of samples is-pCffonned bv Polarized Light Micro .copy (PLM) - Point Counting Method (EPA 60O/M4-82-O20) * Analytical equipments; Stereobinocular microscope (MEIJI EMT-Serial # 25930). Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) ♦ PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically- bound materials. Quantitative transmission electron micros ropy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. ♦ The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsem ;nt by NVLAP or any agency of the US Government. i\ YS-DOH ELAP # 11273 NIST-M'LAP If 102047 AIHA tf: 100269

•)

CITY_21MC100_0 02777713

NYC-WTC_000266361

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266361Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →