NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 7 pages

Bulk sample analysis report, 1 Centre Street, 2001

Machine-extracted title · confidence 48%

Air/bulk sample analysis for NYC-DCAS at 1 Centre Street, NYC, with lab IDs and location details.

NYC-WTC_000266360–000266366
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAUCONSUIJANTS 35-4(1 StthStmt

a Long Island City N9wYork,fflO€ Ifll:p1«)729-199J Fax; {718)729-1875

BULK SAMPLE ANALYSIS REPORT CLIENT; NYC-DCAS BUILDING ADDRESS: 1 CENTRE STREET PROJECT#: Client Sample ID# 26 27 28 29 30 Lab Sample ID^ • 010917B-846 010917B-847 010917B-848 010917B-849 010917B-850

Sample Location 5th Floor 5th Floor Ground Floor Ground Floor Ground Floor North corridor East Elevator North Elev North Elevator North Elevator Stair "A” Lobby Lobby West Lobby Lobby West Exit Exit Homogeneity Yes Yes Yes Yes Yes

Sample Description Door Step Sill Floor Floor Floor Wipe Wipe Wipe \\ ipe Wipe

Color BIk BIk BIk BIk BIk

Texture Mixed Mixed Mixed Mixed Mixed

Sample Treatment None None None None None

Asbestos Present. (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent) 5%SYNTH 10%CELL 5%SYNTH 2%CELL l0%CELL 5%SYNTH Non Fibr. Mat (Percent)- 95% 85% 95% 98% 90% Date Received. 9/17/01 Date of Analysis- 9/17/01 Date of Report 9/17/01

Analyst Lab Manamr: 7? ouvaras David Chen * Analysis of samples is performed by Polarized Light Microscopy (PLM) - Point Counting Method (EPA 6OO/M4-82-020) * Analytical equipments. Stereobinocular microscope (MELI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-ffiable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated a; non-asbestos-containing * Samples will be stored for ninety (90) days and then returred to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without tho written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. i\ YS-DOH ELAP 1(11273 yiST-N^LAP » 102047 A/f/A 100269

6

CITY_21MC100_002777717

NYC-WTC_000266365

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266365Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →