KAMCONSUUANIS 35-«361h SfrMi Long Island City NewYorkJUM T»I:{T1»)J29.1997 Fax: {718)729-1876

BULK SAMPLE AfiALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 1 CENTRE STREET PROJECT#: Client Sample ID- . 31 33 34 Lab Sample ID- 010917B-851 010917B-852 010917B-853 010917B-854

Sample Location Ground Floor Ground Floor Ground Floor Ground Floor South West South East South - South North - North Entrance Entrance Entrance Lobby Entrance Lobby

Homogeneitx Yes Yes Yes 'll es

Sample Description Floor Floor Floor Floor Wipe Wipe Wipe W ipe

Color Blk Blk Blk Blk

Texture Mixed Mixed Mixed Mixed

Sample Treatment None None None None

Asbestos Present. (Type & Percent) ND ND ND ND Total Percent Asbestos; 0% 0% 0% 0%

Other Fibr. Mat. (Type & Percent): 5%SYNTH 10%CELL IO%CELL 10%CELL

Non Fibr Mat. (Percent). 95% 90'>-o 90% 90% Date Received 9/17/01 Date of Analysis 9/17/01 Date of Report- 9/17/01

Analyst^ .ouvaras * Analysis of samples is (Jerfbrmed bv Polarized Light Microicopv fPLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in fo k coverings and similar non-ftiable organically bound materials Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returm d to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory * The report must not be used bv the client to claim endorsement by NVLAP or any agency of the US Government. i\YS-DOH ELAP//1/273 MST-i\yLAP »102047 A/HA »: 100269

CITY_21MC100_002777718

NYC-WTC_000266366

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266366Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →