Bulk sample analysis report, NYC-DCAS, 60 Manhattan

Machine-extracted title · confidence 42%

Laboratory analysis of bulk samples for NYC-DCAS at 60 Manhattan building address.

NYC-WTC_000266372–000266383
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAMCONSUIMS 35-40 36th Street Long Island City New York, 11106 W:{m)729.W Fax:(718)729-1876

BULK SAMPLE A^ ALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 60 Centre Street, Manhattan, NY PROJECT#: Client Sample ID# • 56 57 58 59 60 Lab Sample ID# 010919B-1177 010919B-1178 010919B-1179 010919B-1180 010919B-1I81 Sample Location Basement Rear 1st Floor 1st Floor Basement Female Basement Female Entrance Lobby Mam Entrance Mam Entrance Officer Locker Officer Locker Floor Lobby Floor Lobby Floor Room Ceiling Room Top Vent E.xhaust of Desk Homogeneity Yes Yes Yes Yes Yes

Sample Description Dust Dust Dust Dust Dust Wipe Wipe VV ipe Wipe Wipe

Color Blk Blk Blk Blk Blk

Texture. Mi.xed Mi.xed Mi.xed Mixed Mi.xed

Sample Treatment None None None None None

Asbestos Present. (Type & Percent) ND ND ND ND ND Total Percent Asbestos; 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 2%CELL 3%CELL 10%SYNTH 10%SYNTH 2%SYNTH <1%FBGL <1%FBGL 2%CELL 2%CELL Non Fibr. Mat. (Percent): 97% 96% 88% 88% 98% Date Received 9/19/01 Date of Analysis 9/19/01 Date of Report. 9/19/01 Analystu^ Lab Manager: ) Roody LoJis David Chen * Analysis of samples is performed larized Light Micros ;opv (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments Stereobinocular microscope (MEIJI SMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floo- coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) davs and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsemeit by NVLAP or any agency of the US Government. i\YS-DOH ELAP 11273 MST-NVLAP tf 1(2047 AIHA »: 100269

L

CITY_21MC100_002777735

NYC-WTC_000266383

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266383Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →