NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 12 pages

Bulk sample analysis report, NYC-DCAS, 60 Manhattan

Machine-extracted title · confidence 42%

Laboratory analysis of bulk samples for NYC-DCAS at 60 Manhattan building address.

NYC-WTC_000266372–000266383
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-4036th Street Long Island City NewYork.t1106 Tel:(718)729-W Fax: (718)729-1876

BULK SAMPLE AfJALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 60 Centre Street, Manhattan, NY PROJECT#: Client Sample ID# . 51 52 53 54 55 Lab Sample ID# 010919B-1172 0109I9B-1173 010919B-1174 010919B-1175 0109I9B-1176

Sample Location- Room 119 Room 119 Basement Male Basement Male Basement Male Window Sill Top of Desk Officer Locker Officer Locker Officer Locker Room Ceiling Room Top Room - Top Vent E.xhaust of Desk of Lockers Homogeneity Yes Yes Yes Yes Yes

Sample Description Dust Dust Dust Dust Dust Wipe Wipe Wipe Wipe Wipe

Color. Blk Blk Blk Blk Blk

Texture: Mixed Mixed Mixed Mixed Mixed

Sample Treatment' None None None None None

Asbestos Present- (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 3%SYNTH 2%SYNTH 5%SYNTH 10%SYNTH 2%CELL 2%CELL Non Fibr. Mat (Percenti­ 97% 98% 95% 88% 98% Date Received- 9/19/01 Date of Analysis- 9/19/01 Date of Report: 9/19/01

Analyst Lab Manager: [____ tl Roody Louj David Chen * Analysis of samples is performed irized Light Micro .copy fPLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containmg * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsem :nt by NVLAP or any agency of the US Government. NYS-DOH ELAP # 11273 MST-Nf^LAP 0 102047 AIHA#; 100269

11

CITY_21MC100_002777734

NYC-WTC_000266382

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266382Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →