Bulk sample analysis report, 49-51 [name]

Machine-extracted title · confidence 44%

Bulk sample IDs and locations for DCAS project at 49-51 [name], 14th Floor.

NYC-WTC_000266401–000266405
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

35-40 36th StfMt Long Island City Nswrork,11106 Tel: (718)729-1997 Fax; (718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 49-51 Chamber Street PROJECT#: Client Sample ID# ; 16 17 18 19 20 Lab Sample ID# 0I0918C-999 010918C-1000 010918C-100I 0I0918C-1002 010918C-1003 Sample Location. Staircase "E" Elevator Lobby- Elevator Lobby Staircase E File Cabinet by East East East East Elevator #5 5th Floor 5th Floor 3rd Floor 3rd Floor 3rd Floor

Homogeneity- Yes Yes Yes Yes Yes Sample Description Floor Floor Floor Floor Cabinet File Wipe W ipe Wipe Wipe W'ipe

Color- Blk Blk Blk Blk Blk Texture Mixed Mixed Mixed Mixed Mixed Sample Treatment None None None None None

Asbestos Present; (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent): 15%CELL 5%CELL 5%CELL 4%CELL 7%CELL 3%SYNTH 10%SYNTH 5%SYNTH Non Fibr Mat. (Percent): 85% 92% 85% 96% 88% Date Received- 9/18/01 Date of Analysis 9/18/01 Date of Report: 9/18/01

Analyst: Lab Man 'er: L Roodv Louk David Chen * Analysis of samples is performed b\ Polarized Light Microsi opv (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments; StereobifrtJ^lar microscope (MEIJI :MT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM IS not consistently reliable in detecting asbestos in floo; coverings and similar non-ffiable organically bound materials. Quantitative transmission electron microsc ?pv is currently the only method that can be used to determine if this material can be considered or treated as r on-asbestos-containing * Samples will be stored for ninety (90) days and then returnee to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the v ritten approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. WS-DOH ELAP 1/11273 NLST-NyLAP # 102047 AIHA 4: 100269

4

CITY_21MC100_0 02777762

NYC-WTC_000266404

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266404Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →