NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 13 pages

Bulk sample analysis report, 80 [name]

Machine-extracted title · confidence 43%

Bulk sample IDs and room labels for 80 [name], 8th Floor and East/West areas.

NYC-WTC_000266439–000266451
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ivwuuiKvunnia 35-W36t)iStrMt Long Island City IP <1 NewYoik,11106 Tel: (718)729-1997 c. k. Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: NYC-DCAS BUILDING ADDRESS: 80 Centre Street, Manhattan, NY PROJECT#: Client Sample tD4 56 57 58 59 60 Lab Sample ID- • 010922C-1494 010922C-I495 010922C-1496 010922C-1497 0I0922C-1498

Sample Location Mam Lobby Centre Street Worth Street Connecting Hallwa; Basement Elevators Mam Entrance Mam Entrance Mam Lobby & Stairs C Access Facing West Facing South Corridor By 136 Homogeneity Yes Yes Yes Yes Yes

Sample Description Door Step Floor Floor Floor Floor W ipe U ipe W ipe W ipe Wipe

Color BIk BIk BIk BIk BIk

Texture Mixed Mixed Mixed Mixed Mixed

Sample Treatment None None None None None

Asbestos Present. (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0% Other Fibr. Mat. (Type & Percent) 3%CELL 1%CELL 5%CELL 5%CELL l0%CELL

Non Fibr Mat (Percent); 97% 99% 95% 95% 90% Date Received. 9/22/01

j2 Date of Analysis. 9/23/01 Date of Report; 9/24/01

Analyst: ' ULvw Xi U-1 Lab Manager: v-— \Tark Ulanecki David Chen * Analysis of samples is performed bv Polarized Liaht Micro' copy (PLM) - Point Counting Method (EPA 600/^14-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Liaht Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials Quantitative transmission electron micros ;oov is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used bv the client to claim endorsem'‘nt by NVLAP or any agency of the US Government. \YS-DOH ELAP # 11273 MST-NYLAP tf 102047 AIHA tf: 100269

12

CITY_21MC100_002777808

NYC-WTC_000266450

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266450Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →