NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos Inspection, 130 Liberty Street, Nov 2008

Machine-extracted title · confidence 40%

Asbestos inspection record for 130 Liberty Street with block/lot and city data, dated 11/04/08.

NYC-WTC_000266101
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 11/04/08 Floor Zip Borough Block Lot Squad # Badge # Various 10006 1 54 1 1 . A062 Inspector Building Type Basis of Inspection Photos Taken M.Gagnidze_____ F TRU0086MN08 yes Contractor's Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner's Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person- Time of Inspection from: Arnel Javal, Sr. Proj. Mgr/TRC Environmental 9:30 pm to 10:30 pm

I arrived at the premise at 9:30 pm. LVI schedule informed that activities include scrape areas 1 & 5, box debris on 9'” and 8'*’ floors, demo, box debris, clear off floors on 7'^ and O'” floors, scrape areas at spandular beam, box debris on 4'" floor.

I proceeded to the decon, signed the log book, don the appropriate level of personal protective equipment to enter the regulated area on S’” floor. Negative air pressure on the floor was 0.063. I used B stairwell to go to 9*" floor.

9**' Floor - 32 workers were found on the floor in the process of scraping the fireproofing on the SouthAA/est side, spraying with amended water around the area, picking up debris from the floor and placing into the boxes; on the North/East side workers were on scaffolds fine cleaning the ceiling, spraying with amended water and cleaning the floor from ceiling cleaning. Others were wrapping debris with poly, preparing boxes, replacing the filters of micro trap machines, 20 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents. 10 Gaylord boxes were ready to be taken out. I used B stairwell to go to the S'” floor.

S'^FIoor - 33 workers were present on the floor. Workers on 5 scaffolds on West side of the work area were scraping the beams and columns from fireproofing, spraying with amended water, picking up debris and placing into to the boxes, plasticizing the platforms inside the shaft area, boxing debris. 10 Gaylord boxes were ready for load out. Inspection was done on micro trap machines and tents. 1 observed excess water on the floor on north side of the work area and 2 micro trap machines were without filters. Handler Supervisor was advised to direct workers to pick up the water and place the filters on micro traps. I used B stairwell to proceed to the 7"’ floor

7”' Floor - No activities or personnel observed on the floor 20 micro trap machines were powered on and 5 on stand by. Using B stairs I went to the 6*’’ floor. 6*'’ Floor - No activities or personnel observed on the floor 10 Gaylord boxes were ready to be taken out. Inspection was done on micro trap machines and tents. I used B stairs to proceed to the 4'" floor. 4’'' Floor - 5 workers were present on the floor, boxing debris, washing and loading out Gaylord boxes from the South side waste decon. 10 Gaylord boxes were ready to be taken out. 20 micro trap machines were powered on and 5 on stand by. Inspection was done on micro trap tents. I used B stairs to go back to the 8"’ floor, proceeded to the decon.

After following the decontamination procedure I signed the log book and used north hoist to return to the ground floor. Inspection was done on ATC trailers.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor’s Initial

Borough I “Manhattan 2“I3ronx 3=Brookiyn 4=Queens 5=Richmond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code I “ Violation Issued 2=No Violation Issued 3=No access 4=Project not started (no NOV) 5=Public Owned Properly

CITY_DEP_WORBY_CANNATA_SUBP_000131308

NYC-WTC_000266101

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000266101Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →