Asbestos Inspection Report

Premise No. Inspection Date: 130 Liberty Street 09/15/08 Floor Zip Borough Block Lot Squad # Badge # Various 10006 1 54 1 1 A062 Inspector Building Type Basis of Inspection Photos Taken MGagnidze F TRU0086MN08 No Contractor's Name Sample Number LVI Environmental Address City Sample Number

State Zip Phone Sample Number

Laboratory Name Owner’s Name TRC Environmental Corp The Lower Manhattan Development Corp. Address City Address City 1340 Broadway New York One Liberty Plaza New York State Zip Phone State Zip Phone NY 10018 NY 10006 (212) 962-2300 Contact Person Time of Inspection from: Arnel Javal, Sr. Proj. Mgr/TRC Environmental 4:50 pm to 6:00 pm

I arrived at the premise at 4:50 pm. LVI schedule informed that activities include scraping, boxing debris on 13“' floor, cutting raceways, boxing debris on 12'" floor, demo, boxing debris on 11‘" and 10'" floors. I entered the decon area, suit up, don respirator and entered containment on 13'" floor.

13'" Floor - 24 workers were present on the floor in shift. Workers were preparing boxes, changing the filters on micro trap machines. I observed that exhaust duct of one of the micro trap machines was cut off. Supervisor Luis began repairing the damage immediately. Then I noticed water on the floor on north side of working area. Workers started vacuuming the water from the floor. Others were sealing critical barriers on south and west side of the area in preparation for fireproofing removal. 20 Gaylord boxes were sprayed with amended water and ready to be taken out. Inspection was done on micro trap machines and micro trap tents, air monitoring pumps were on. I used B stairs to proceed to the 12*" Floor.

12'" Floor - 18 people were working on site. Workers were on the south side of the vestibule, using 7 scaffolds to cut the raceways, spraying the area with amended water, vacuuming the floor, loading out boxes from the decon, there still was 16 boxes ready to be taken out. Others were boxing debris and spraying with amended water. 20 micro trap machines were powered on and 5 were on stand by. I indicated that filters of the machines were dirty and needed to be replaced. Inspection was done on micro trap tents. I observed that bottom of the fire door needed to be re-sealed with duct tape, which was immediately repaired. Using B stairwell I proceed to 11'" Floor.

1l" Floor - There were 24 workers on the floor in the process of re-sealing the door of electrical room, boxing debris, spraying with amended water, cutting metal into pieces with HEPA vacuum attached, numerous amount of poly wrapped beams, which have been sprayed with amended water, were present in various areas of the floor. 42 Gaylord boxes were on the floor ready for load out. 20 micro trap machines were on and 5 were on stand by. Inspection was done on micro trap tents, I used B stairs to proceed to the 10'" floor.

10'" Floor - 25 workers were working in shift. Workers were observed on 2 scaffolds and ladders removing metals from the ceiling using hammer, cutting metal fixtures, using power tools with HEPA vacuum attached, placing debris to the boxes and spraying with amended water. Inspecting the critical barriers, removing insulation, wrapping beams with poly, 23 Gaylord boxes were ready for load out, 20 micro trap machines were on and 5 on stand by. I used B stairwell to go back to the 13" floor. After following the decontamination procedure I signed the log book and used north hoist to get to the ground floor. Inspection was done on ATC trailer.

NOV# Infraction Infraction Infraction Infraction

NOV# Infraction Infraction Infraction Result Code 2 NOV# Infraction Infraction Infraction Supervisor's Initial ,

Borough I ^Manhattan 2~Bronx 3=Brooklyn 4=Queens 5—Richmond Building Type A >6 stories B <6 stories C single family D school E hospital F public owned Result Code 1 = Violation Issued 2=No Violation Issued J-No access 4=Project not started (no NOV) S-Public Owned Property

CITY_DEP_WORBY_CANNATA_SUBP_000130573

NYC-WTC_000265871

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000265871Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000266101

Asbestos inspection record for 130 Liberty Street with block/lot and city data, dated 11/04/08.

Similar indexed content

Compare copies and versions →