N: Secret abatement of EPA building in NYC - 248

Region 2 was also reminded at the time by the very laboratory data sheets showing the positive TEM results for its building that EPA required the use of TEM. At the bottom of every table giving the results of the analyses for the bulk dust analyses on the 290 Broadway building, SciLabs included the following statement, reminding its clients of the obligations under EPA guidance and NY State regulations to perform TEM for both floor covering and similar materials, and that TEM was the appropriate method;

Note: PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. TEM is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos­ containing in New York State (see also EPA Advisory for floor tile, FR 59, 146, 38970, 8/1/94).

It is interesting and telling that Region 2 withheld the testing data on its building when responding to a 9/21/01 Freedom of Information Act (FOIA) request from the New York Environmental Law and Justice Project (NYELJP). The testing at 290 Broadway would have been responsive, since the FOIA requested all documents meeting the following description;

[A]ll monitoring data, studies and reports of air, dust, bulk (including but not limited to hazardous materials and water samples) taken from September 11, 2001 to present in response to the World Trade Center disaster (including but not limited to lower Manhattan and Staten Island land fills).

It is also interesting and telling that Region 2 omitted the fact that TEM testing of dusts was performed at its own building in a February 22, 2002 letter from EPA Administrator Whitman to Congressman Nadler. Ms. Whitman was explaining both the testing that had been performed at Region 2's offices in Manhattan, as well as the asbestos abatement which took place. In an attachment to her letter, the dust testing was "incorrectly" described as being only by the PLM method. In fact, both methods were used, TEM and PLM.

In 1998, Region 2 used TEM extensively for assessing the cleanup of another federal building

Region 2 is reportedly offering the excuse of confusion and panic after the collapse of the WTC for only using PLM testing, instead of the required TEM testing of dusts. But this argument has no merit for the following reason;

Bob Fitzpatrick, the Region 2 Asbestos Coordinator, was directly involved in the oversight of an asbestos abatement for the INS at 26 Federal Plaza during the 1998 time period, which extensively used TEM testing of dusts. After the WTC disaster. Bob Fitzpatrick was and is the Region 2 Asbestos Coordinator, responsible for the evaluation and oversight of asbestos abatement and control. Thus, Region 2 cannot claim to have no institutional knowledge of the need or requirements for TEM testing of bulk dusts. It is not as though they had to research the issue for the first time.

The following describes the 1998 abatement; Roofing work had resulted in the dropping of asbestos insulation onto the suspended ceiling tiles on the 16th floor at 26 Federal Plaza in Manhattan, the offices of the Immigration and Naturalization Service (INS). The General Service Administration hired an asbestos abatement firm who initially did a

NYC-WTC_000251404

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251404Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →