The documents supplied by Region 2 show that air sampling was performed on 9/13, followed by dust sampling and additional air sampling on 9/14. On the basis of the results, transmitted back to Region 2 on 9/15, Reg. 2 decided to abate its own building for asbestos.

Region 2 used more sensitive testing procedures for its own building than it used for samples for other parts of the city, including what it called "the; contaminated zone" south of Warren Street and west of Broadway. Its building was not even in this contaminated zone, being 2 blocks north of it.

For bulk dust samples (dusts on surfaces) in other parts of the city. Region 2 only used polarized light microscopy (PLM). This is an older cruder laboratory method that can only reliably detect asbestos at concentrations at about 1%, but can sometimes find asbestos at concentrations as low as 0.1%. Region 2 was able to detect asbestos only as low as 0.25% by PLM after the WTC disaster, but typically could only measure concentrations at 1% or higher.

However, Region 2 also used transmission electron microscopy (TEM) to test whether asbestos was present, a very sensitive laboratory method, for its own building. This method can probably detect the presence of asbestos down to at least 0.001% or even lower in dusts and soils

Region 2 did detect asbestos in dust samples at 290 Broadway by using TEM, but could not detect any in the same dusts using PLM.

The TEM tests of the dusts did not find actual concentration levels. It was a qualitative test, which only tells if asbestos is there or not. But clearly, the concentrations would be lower than 1%, or even 0.25%, the lowest levels that could be detected by PLM, because no asbestos was found using PLM.

Region 2 has advised the public that only dusts containing 1% or more asbestos are considered "asbestos containing." But it took action to abate its own building at much lower levels.

Region 2 never detected any asbestos in the air in its building (the air testing methods were not more sensitive than it used in the contaminated zone around Ground Zero). So this was not the reason for cleaning its building.

Thus, while Region 2 was advising the public that only air of 70 structures per square millimeter and dusts over 1% were considered hazardous, it used taxpayer dollars to clean up its own buildings which were contaminated with much lower levels than these alleged standards.

Most importantly, however, is the fact that Region 2 used the more sensitive laboratory method for its own building.

At the same time that it planned using the sensitive TEM tests for its building. Region 2 refused an offer from Region 8 on 9/12. Region 8, who was 2

CITY_21MC100_013381542

NYC-WTC_000250728

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250728Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →