EPA memo on air and dust asbestos testing, Mar 2002

Machine-extracted title · confidence 50%

EPA memo documenting issues with asbestos testing standards post-WTC collapse.

NYC-WTC_000250730–000250772
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

DIFFERENCE IN TESTING METHODS AND SENSITIVITIES FOR: - EPA Region 2 building at 290 Broadway - All of Manhattan and surrounding NYC after WTC collapse - After the first bombing of the World Trade Center

2 TEM Air NEGATIVE low sensitivity air tests using at Region 2 building, M 9 transmission electron 290 Broadway, inside A 0 microscope (TEM) lab and outside lobby, N instruments except 1 sample out H B of the 47 had 25 A r s/mm^, below what Region 2 calls "safe." T o The detection limits T a (sensitivities) of the A d air tests ranged from N w 16.7 - 25 s/mm’ a y

E PLM Dusts on NEGATIVE P low sensitivity polarizing light Surfaces at Region 2 building, microscopes which can see only 290 Broadway A and bulk larger asbestos fibers and can dusts only reliably give concentrations for 1 % or higher

TEM Dusts on POSITIVE at Region high sensitivity transmission surfaces 2 building, 290 electron microscopes which con Broadway. EPA and bulk see the smaller asbestos fibers guidance requires dusts TEM on dusts and ond can also see them in much lower concentrations in dusts, other bulk materials probably lower than 0.00 1 %. for thin fibers under See 59 FR 38970 forAHERA both AHERA and the and 59 FR 542 for NESHAP NESHAP requirement to use TEM on solid bulk materials.

Offered to EPA Region 2 SEM Dusts on by Region 8 for free for high sensitivity scanning electron surfaces microscopes which can see the Manhattan after WTC and bulk smaller asbestos fibers and con collapse. Also used after dusts also see them in much lower first bombing of WTC in concentrations in dusts, 1993 probably lower than 0.001%

-38-

CITY_21MC100_013381587

NYC-WTC_000250767

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000250767Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →